@ -183,9 +183,56 @@ groups:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: UPS battery is detected to replace
|
||||
|
||||
|
||||
|
||||
- name: Node_alerts
|
||||
rules:
|
||||
- alert: HostOutOfMemory
|
||||
expr: (node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10)
|
||||
for: 2m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: Host out of memory (instance {{ $labels.instance }})
|
||||
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
- alert: HostMemoryUnderMemoryPressure
|
||||
expr: (rate(node_vmstat_pgmajfault[1m]) > 600) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}
|
||||
for: 2m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: Host memory under memory pressure (instance {{ $labels.instance }})
|
||||
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
- alert: HostOutOfDiskSpace
|
||||
expr: ((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0)
|
||||
for: 2m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: Host out of disk space (instance {{ $labels.instance }})
|
||||
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
- alert: HostHighCpuLoad
|
||||
expr: (sum by (instance) (avg by (mode, instance) (rate(node_cpu_seconds_total{mode!="idle"}[2m]))) > 0.8)
|
||||
for: 10m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: Host high CPU load (instance {{ $labels.instance }})
|
||||
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
- alert: HostUnusualDiskWriteLatency
|
||||
expr: (rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0)
|
||||
for: 2m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: Host unusual disk write latency (instance {{ $labels.instance }})
|
||||
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
- alert: HostUnusualDiskReadLatency
|
||||
expr: (rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0)
|
||||
for: 2m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: Host unusual disk read latency (instance {{ $labels.instance }})
|
||||
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
||||
EOH
|
||||
}
|
||||
|
||||
|